Alert Name : al_switch
Object Type : interface
Object Name : swport01
Message : 50000197: Port 1 has become ACTIVE
eqcli >
To show the first notification matching one or more filters enter:
eqcli > show notification first alert_type alerttype object_type objecttype object_name
objectname
If the object_name is specified, object_type must also be specified.
The following is an example showing the state change for swport01 above.
eqcli > show notification first alert_type state_change object_type
interface object_name swport01
Notification ID : 1
Alert Type : state_change
Alert Subtype : Up
Alert Name : al_switch
Object Type : interface
Object Name : swport01
Message : 50000197: Port 1 has become ACTIVE
eqcli >
Setting the Interval
To set the interval at which alert notifications are displayed on the CLIenter the following:
eqcli> user-tou*> alert_interval integer
By default alert_interval is 1 minute. The maximum is 86400 (1 day).
Removing Notification Alerts
You can remove
all
notification alerts by entering:
eqcli > no notification all
Remove
individual
notifications using the ID number by entering:
Copyright © 2013 Coyote Point Systems. A subsidiary of Fortinet, Inc.