Alert Type Object Type When an alert is generated
exception Peer An alert is generated whenEqualizer has received a heartbeat from a peer on a
subnet on which it had previously lost contact.
exception Peer An alert is generated when failover is disabled because of a configuration
mismatch.
exception Peer An alert is generated when a VLAN/subnet mismatch is detected and reports the
error.
exception Peer An alert is generated when a previously reported VLAN/subnet mismatch is
resolved.
state_change Peer An alert is generated when a failover group has transitioned from one mode to
another. For example it may change from Primary to Backup.
state_change Peer An alert is generated when the local peer has transitioned from one mode to
another. For example from Primary to Backup.
state_change Peer An alert is generated for state change for allfailover peers and failover groups
(aka "F/O Group" or "fogrp: in the CLI and GUI). This applies to both local and
remote failover peers and groups. You can now define a state change alert on
any local or remote peer definition or failover group, and if that peer or failover
group changes state, the alert will fire on the system on which the alert is
configured.
exception Peer An alert is generated when connectivity has been regained on a particular VLAN
on which connectivity was previously lost.
exception Peer An alert is generated when connectivity has been regained on a particular VLAN
on which connectivity was previously lost.
exception Peer An alert is generated when connectivity was lost on a particular VLAN port or
ports.
exception Peer An alert is generated when connectivity has been regained on a particular VLAN
port or portson which connectivity was previously lost.
state_change Server An alert is generated when a server has been marked up or down by Layer 3
probes.
state_change Interface An alert is generated when a front panel port has been marked UP or DOWN, or
when an internal motherboard port has been marked DOWN.
Alert Notification Types
Currently, the email, syslog, snmp, and ui notification types are supported. Multiple notification types can be
specified for a single alert.
1. email - Sends an email to the specified recipients, using a specified SMTP relay mail server. When this
notification type is used, an email address is also required. A subject line for the email is optional.
2. syslog - Sends an alert message to the system log.