Deploying Equalizer with MS Terminal Services
Deployment Guide
© 2010 Coyote Point Systems, Inc. All Rights Reserved. | www.coyotepoint.com 11
2. In the left panel of the Server Manager, click the plus sign next to Roles to
expand the Roles list, then click the plus sign next to Terminal Services to
expand that list.
3. Click on Terminal Services Configuration.
4. In the right panel, under Connections, right-click on the Connection Name
(default is RDP-Tcp) and select Properties.
5. Click on the Sessions tab (see Figure 1.7):
The screen above shows the default session options.
6. Click on Override user settings to enable the check box, and select a
session time equal to the sticky time you set in Step 2.
Continue with the next step.
Step 7: Set MS Terminal Server Maximum Connections
1. Click on the Network Adapter tab. Click on Maximum connections and set
the same value you set for max connections on Equalizer in Step 5 (in our
example, 75).